1.
Artículo en Inglés | MEDLINE | ID: mdl-38300188

RESUMEN

PURPOSE: A first of its kind experimental verification of dose-averaged linear energy transfer (LETd) optimized treatment plans for proton therapy has been carried out using a silicon-on-insulator microdosimeter at the Massachusetts General Hospital (MGH), Boston, USA. METHODS AND MATERIALS: Three clinical treatment plans of a typical ependymoma structure set were designed using the standard clinical approach, the proposed protocol approach, and a one-field approach. The plans were then reoptimized to reduce the LETd-weighted dose in the brain stem. All six plans were delivered in a solid water phantom and the experimental yD‾ measured. RESULTS: After LETd optimization, a reduction in yD‾ was found within the brain stem by an average of 12%, 19%, and 4% for the clinical, protocol, and one-field plans, respectively, while maintaining adequate coverage of the tumor structure. The experimental LETd-weighted doses were in agreement with the treatment planning system calculations and Monte Carlo simulations and reinforced the improvement of the optimization. CONCLUSIONS: This work demonstrates the first experimental verification of the clinical implementation of LETd optimization for patient treatment with proton therapy.

2.
Radiat Prot Dosimetry ; 199(15-16): 1968-1972, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819306

RESUMEN

In proton therapy, most treatment planning systems (TPS) use a fixed relative biological effectiveness (RBE) of 1.1 all along the depth-dose profile. Innovative TPS are now investigated considering the variability of RBE with radiation quality. New TPS need an experimental verification in the quality assurance (QA) routine in clinics, but RBE data are usually obtained with radiobiological measurements that are time consuming and not suitable for daily QA. Microdosimetry is a useful tool based on physical measurements which can monitor the radiation quality. Several microdosimeters are available in different research institutions, which could potentially be used for the QA in TPS. In this study, the response functions of five detectors in the same 62-MeV proton Spread Out Bragg Peak is compared in terms of spectral distributions and their average values and microdosimetric RBE. Their different response function has been commented and must be considered in the clinical practice.


Asunto(s)
Terapia de Protones , Protones , Radiometría , Efectividad Biológica Relativa
3.
Phys Med Biol ; 66(9)2021 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-33761472

RESUMEN

Proton therapy has a distinct dosimetric advantage over conventional photon therapy due to its Bragg peak profile. This allows greater accuracy in dose delivery and dose conformation to the target, however it requires greater precision in setup, delivery and for quality assurance (QA) procedures. The AAPM TG 224 report recommends daily range and spot position checks with tolerance on the order of a millimetre. Daily QA systems must therefore be efficient for daily use and be capable of sub-millimetre precision however few suitable commercial systems are available. In this work, a compact, real-time daily QA system is optimised and characterised for proton range verification using an ad-hoc Geant4 simulation. The system is comprised of a monolithic silicon diode array detector embedded in a perspex phantom. The detector is orientated at an angular offset to the incident proton beam to allow range in perspex to be determined for flat proton fields. The accuracy of the system for proton range in perspex measurements was experimentally evaluated over the full range of clinical proton energies. The meanR100,R90andR80ranges measured with the system were accurate within ±0.6 mm of simulated ranges in a perspex phantom for all energies assessed. This system allows real-time read-out of individual detector channels also making it appropriate for temporal beam delivery diagnostics and for spot position monitoring along one axis. The system presented provides a suitable, economical and efficient alternative for daily QA in proton therapy.


Asunto(s)
Terapia de Protones , Fantasmas de Imagen , Protones , Radiometría , Dosificación Radioterapéutica , Silicio
5.
Med Phys ; 48(1): 19-56, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32392626

RESUMEN

BACKGROUND: Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. AIMS: To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. MATERIALS AND METHODS: G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. RESULTS: This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. DISCUSSION: Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. CONCLUSION: The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.


Asunto(s)
Benchmarking , Física , Radiometría , Simulación por Computador , Método de Montecarlo
6.
Phys Med Biol ; 65(24): 245018, 2020 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-33086208

RESUMEN

Proton beams are widely used worldwide to treat localized tumours, the lower entrance dose and no exit dose, thus sparing surrounding normal tissues, being the main advantage of this treatment modality compared to conventional photon techniques. Clinical proton beam therapy treatment planning is based on the use of a general relative biological effectiveness (RBE) of 1.1 along the whole beam penetration depth, without taking into account the documented increase in RBE at the end of the depth dose profile, in the Bragg peak and beyond. However, an inaccurate estimation of the RBE can cause both underdose or overdose, in particular it can cause the unfavourable situation of underdosing the tumour and overdosing the normal tissue just beyond the tumour, which limits the treatment success and increases the risk of complications. In view of a more precise dose delivery that takes into account the variation of RBE, experimental microdosimetry offers valuable tools for the quality assurance of LET or RBE-based treatment planning systems. The purpose of this work is to compare the response of two different microdosimetry systems: the mini-TEPC and the MicroPlus-Bridge detector. Microdosimetric spectra were measured across the 62 MeV spread out Bragg peak of CATANA with the mini-TEPC and with the Bridge microdosimeter. The frequency and dose distributions of lineal energy were compared and the different contributions to the spectra were analysed, discussing the effects of different site sizes and chord length distributions. The shape of the lineal energy distributions measured with the two detectors are markedly different, due to the different water-equivalent sizes of the sensitive volumes: 0.85 µm for the TEPC and 17.3 µm for the silicon detector. When the Loncol's biological weighting function is applied to calculate the microdosimetric assessment of the RBE, both detectors lead to results that are consistent with biological survival data for glioma U87 cells. Both the mini-TEPC and the MicroPlus-Bridge detector can be used to assess the RBE variation of a 62 MeV modulated proton beam along its penetration depth. The microdosimetric assessment of the RBE based on the Loncol's weighting function is in good agreement with radiobiological results when the 10% biological uncertainty is taken into account.


Asunto(s)
Terapia de Protones , Radiometría , Efectividad Biológica Relativa , Humanos , Silicio
7.
Phys Med Biol ; 65(21): 215015, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-32756019

RESUMEN

BrachyView is a novel in-body imaging system developed to provide real-time intraoperative dosimetry for low dose rate prostate brachytherapy treatments. Seed positions can be reconstructed after in-vivo implantation using a high-resolution pinhole gamma camera inserted into the patient rectum. The obtained data is a set of 2D projections of the seeds on the image plane. The 3D reconstruction algorithm requires the identification of the seed's centre of mass. This work presents the development and techniques adopted to build an algorithm that provides the means for fully automatic seed centre of mass identification and 3D position reconstruction for real-time applications. The algorithm presented uses a local feature detector, speeded up robust features, to perform detection of brachytherapy seed 2D projections from images, allowing for robust seed identification. Initial results have been obtained with datasets of 30, 96 and 98 I-125 brachytherapy seeds implanted into a prostate gel phantom. It can detect 97% of seeds and correctly match 97% of seeds. The average overall computation time of 2.75 s per image and improved reconstruction accuracy of 22.87% for the 98 seed dataset was noted. Elimination processes for initial false positive detection removal have shown to be extremely effective, resulting in a 99.9% reduction of false positives, and when paired with automatic frame alignment and subtraction procedures allows for the effective removal of excess counts generated by previously implanted needles. The proposed algorithm will allow the BrachyView system to be used as a real-time intraoperative dosimetry tool for low dose rate prostate brachytherapy treatments.


Asunto(s)
Algoritmos , Braquiterapia/métodos , Prótesis e Implantes , Dosis de Radiación , Automatización , Humanos , Radioisótopos de Yodo/uso terapéutico , Masculino , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Radiometría , Dosificación Radioterapéutica , Técnica de Sustracción , Factores de Tiempo
8.
J Appl Clin Med Phys ; 21(6): 44-52, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32277745

RESUMEN

PURPOSE: This study investigated the use of high spatial resolution solid-state detectors (DUO and Octa) combined with an inclinometer for machine-based quality assurance (QA) of Volumetric Modulated Arc Therapy (VMAT) with flattened and flattening filter-free beams. METHOD: The proposed system was inserted in the accessory tray of the gantry head of a Varian 21iX Clinac and a Truebeam linear accelerator. Mutual dependence of the dose rate (DR) and gantry speed (GS) was assessed using the standard Varian customer acceptance plan (CAP). The multi-leaf collimator (MLC) leaf speed was evaluated under static gantry conditions in directions parallel and orthogonal to gravity as well as under dynamic gantry conditions. Measurements were compared to machine log files. RESULTS: DR and GS as a function of gantry angle were reconstructed using the DUO/inclinometer and in agreement to within 1% with the machine log files in the sectors of constant DR and GS. The MLC leaf speeds agreed with the nominal speeds and those extracted from the machine log files to within 0.03 cm s-1 . The effect of gravity on the leaf motion was only observed when the leaves traveled faster than the nominal maximum velocity stated by the vendor. Under dynamic gantry conditions, MLC leaf speeds ranging between 0.33 and 1.42 cm s-1 were evaluated. Comparing the average MLC leaf speeds with the machine log files found differences between 0.9% and 5.7%, with the largest discrepancy occurring under conditions of fastest leaf velocity, lowest DR and lowest detector signal. CONCLUSIONS: The investigation on the use of solid-state detectors in combination with an inclinometer has demonstrated the capability to provide efficient and independent verification of DR, GS, and MLC leaf speed during dynamic VMAT delivery. Good agreement with machine log files suggests the detector/inclinometer system is a useful tool for machine-specific VMAT QA.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Aceleradores de Partículas , Dosificación Radioterapéutica
9.
Phys Med ; 69: 52-60, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31830631

RESUMEN

PURPOSE: Dose to the rectum during brachytherapy treatment may differ from an approved treatment plan which can be quantified with in vivo dosimetry (IVD). This study compares the planned with in vivo doses measured with MOSkin and PTW 9112 rectal probe in patients undergoing CT based HDR cervical brachytherapy with Co-60 source. METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses. RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47). CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.


Asunto(s)
Braquiterapia/métodos , Cuello del Útero/efectos de la radiación , Radioisótopos de Cobalto , Recto/efectos de la radiación , Neoplasias del Cuello Uterino/radioterapia , Cuello del Útero/diagnóstico por imagen , Femenino , Humanos , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Semiconductores , Tomografía Computarizada por Rayos X , Neoplasias del Cuello Uterino/diagnóstico por imagen
10.
Phys Med Biol ; 65(3): 035004, 2020 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-31842007

RESUMEN

Compact silicon on insulator (SOI) microdosimeters have been used to characterise the radiation field of many different hadron therapy beams. SOI devices are particularly attractive in hadron therapy fields due to their spatial resolution being well suited to the sharp dose gradients at the end of the primary beam's range. Due to the small size of SOI's sensitive volumes (SVs), which are usually ∼1-10 [Formula: see text]m thick, the fabrication of these devices can present challenges which are not as common for more conventional thickness silicon devices such as silicon spectroscopy detectors. Microdosimetry is the study of the energy deposition in micrometre sized volumes representing biological sites and is a powerful approach to estimate the biological effect of radiation on the micron-scale level, in a cell. However, cell sizes vary extensively translating in different energy deposition spectra. This work studies SV thicknesses between 1 and 100 [Formula: see text]m using Geant4 and examines the impact of SV dimensions on microdosimetric quantities. The quantities studied were the frequency mean lineal energy, [Formula: see text], and the dose mean lineal energy, [Formula: see text]. Additionally the relative biological effectiveness (RBE), estimated by the microdosimetric kinetic model (MKM), is also investigated. To study the impact of the SV thickness, SOI microdosimeters were irradiated with proton, [Formula: see text] and [Formula: see text] ion beams with ranges of ∼160 mm, with the microdosimeter being set at various positions along the Bragg curve. It was found that [Formula: see text] was influenced the least in proton beams and increased for heavier ion beams. Conversely, [Formula: see text] was impacted by the SV thickness the most in proton beams and [Formula: see text] was the least. Similar to [Formula: see text], protons were impacted the most by the SV thickness when estimating the RBE using the MKM. The cause of these differences was largely due to the different densities of the delta electron track structure for the case of [Formula: see text] and the energy transferred to the medium from the primary beam for [Formula: see text].


Asunto(s)
Fantasmas de Imagen , Radiometría/instrumentación , Silicio/química , Humanos , Cinética , Método de Montecarlo , Protones , Radiometría/métodos , Efectividad Biológica Relativa
11.
Phys Med Biol ; 65(4): 045014, 2020 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-31739291

RESUMEN

Microdosimetry is a particularly powerful method to estimate the relative biological effectiveness (RBE) of any mixed radiation field. This is particularly convenient for therapeutic heavy ion therapy (HIT) beams, referring to ions larger than protons, where the RBE of the beam can vary significantly along the Bragg curve. Additionally, due to the sharp dose gradients at the end of the Bragg peak (BP), or spread out BP, to make accurate measurements and estimations of the biological properties of a beam a high spatial resolution is required, less than a millimetre. This requirement makes silicon microdosimetry particularly attractive due to the thicknesses of the sensitive volumes commonly being ∼10 [Formula: see text]m or less. Monte Carlo (MC) codes are widely used to study the complex mixed HIT radiation field as well as to model the response of novel microdosimeter detectors when irradiated with HIT beams. Therefore it is essential to validate MC codes against experimental measurements. This work compares measurements performed with a silicon microdosimeter in mono-energetic [Formula: see text], [Formula: see text] and [Formula: see text] ion beams of therapeutic energies, against simulation results calculated with the Geant4 toolkit. Experimental and simulation results were compared in terms of microdosimetric spectra (dose lineal energy, [Formula: see text]), the dose mean lineal energy, y  D and the RBE10, as estimated by the microdosimetric kinetic model (MKM). Overall Geant4 showed reasonable agreement with experimental measurements. Before the distal edge of the BP, simulation and experiment agreed within ∼10% for y  D and ∼2% for RBE10. Downstream of the BP less agreement was observed between simulation and experiment, particularly for the [Formula: see text] and [Formula: see text] beams. Simulation results downstream of the BP had lower values of y  D and RBE10 compared to the experiment due to a higher contribution from lighter fragments compared to heavier fragments.


Asunto(s)
Radioterapia de Iones Pesados , Método de Montecarlo , Radiometría/métodos , Silicio , Cinética , Modelos Biológicos , Efectividad Biológica Relativa
12.
Australas Phys Eng Sci Med ; 42(4): 1099-1107, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31650362

RESUMEN

The MOSkin, a metal-oxide semiconductor field-effect transistor based detector, is suitable for evaluating skin dose due to its water equivalent depth (WED) of 0.07 mm. This study evaluates doses received by target area and unavoidable normal skin during a the case of skin brachytherapy. The MOSkin was evaluated for its feasibility as detector of choice for in vivo dosimetry during skin brachytherapy. A high-dose rate Cobalt-60 brachytherapy source was administered to the tumour located at the medial aspect of the right arm, complicated with huge lymphedema thus limiting the arm motion. The source was positioned in the middle of patients' right arm with supine, hands down position. A 5 mm lead and 5 mm bolus were sandwiched between the medial aspect of the arm and lateral chest to reduce skin dose to the chest. Two calibrated MOSkin detectors were placed on the target and normal skin area for five treatment sessions for in vivo dose monitoring. The mean dose to the target area ranged between 19.9 and 21.1 Gy and was higher in comparison with the calculated dose due to contribution of backscattered dose from lead. The mean measured dose at normal skin chest area was 1.6 Gy (1.3-1.9 Gy), less than 2 Gy per fraction. Total dose in EQD2 received by chest skin was much lower than the recommended skin tolerance. The MOSkin detector presents a reliable real-time dose measurement. This study has confirmed the applicability of the MOSkin detector in monitoring skin dose during brachytherapy treatment due to its small sensitive volume and WED 0.07 mm.


Asunto(s)
Braquiterapia/instrumentación , Radioisótopos de Cobalto/química , Dosimetría in Vivo , Metales/química , Óxidos/química , Dosificación Radioterapéutica , Semiconductores , Neoplasias Cutáneas/radioterapia , Anciano , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Fantasmas de Imagen
13.
Phys Med ; 66: 66-76, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31563727

RESUMEN

PURPOSE: BrachyView is a novel in-body imaging system developed with the objective to provide real-time intraoperative dosimetry for low dose rate (LDR) prostate brachytherapy treatments. The BrachyView coordinates combined with conventional transrectal ultrasound (TRUS) imaging, provides the possibility to localise the effective position of the implanted seeds inside the prostate volume, providing a unique tool for intra-operative verification of the quality of the implantation. This research presents the first complete LDR brachytherapy plan reconstructed by the BrachyView system and is used to evaluate the effectiveness of an imaging algorithm with baseline subtraction. METHODS: A plan featuring 98 I-125 brachytherapy seeds, with an average activity of 0.248 mCi, were implanted into a prostate gel phantom under TRUS guidance. Images of implanted seeds were obtained by the BrachyView after the implantation of seeds. The baseline subtraction algorithm is applied as a pixel-to-pixel counts subtraction and is applied to every second projection obtained after the implantation of each needle. Seed positions and effectiveness of the baseline reconstruction in the identification of seeds were verified by a high-resolution post-implant CT scan. RESULTS: A complete brachytherapy plan has been reconstructed with a 100% detection rate. This is possible due to the effectiveness of the baseline subtraction, with its application an overall increase of 11.3% in position accuracy and 8.2% increase in detection rate was noted. CONCLUSION: It has been demonstrated that the BrachyView system shows the potential to be a solution to providing clinics with the means for intraoperative dosimetry for LDR prostate brachytherapy treatments.


Asunto(s)
Algoritmos , Braquiterapia , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Técnica de Sustracción , Humanos , Masculino , Fantasmas de Imagen , Prótesis e Implantes , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X , Ultrasonografía
14.
Phys Med ; 60: 150-155, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31000076

RESUMEN

The aim of the present study was to evaluate the response of the MOSkin MOSFET dosimeter for X-ray diagnostic CT beams. Experiments were performed to investigate the sensitivity, energy dependence, reproducibility, fading and angular dependence of the dose response for the device. The dosimeter's performance was evaluated for the standard radiation qualities RQT 8, RQT 9 and RQT 10 in a metrology laboratory. In a CT scanner, the MOSkin was used to assess the air kerma profile and the dose profile in a phantom. The integral of the dose profile was compared to the CPMMA,100 measured with a pencil ionization chamber. The results showed that the MOSkin response was linear and reproducible with doses in the CT range. Energy dependence varied up to a factor of 1.19 among the tested X-ray energies. Angular dependence of the response was not greater than 7.8% within the angle range from 0 to 90 degrees. Signal fading within 3 min was negligible. Additionally, the MOSkin was able to accurately assess the air kerma profile and the integral of the dose profile in a CT scanner. The integral of the dose profile in a phantom was in agreement with the CPMMA,100. The presented results demonstrated the potential of the MOSkin for application in CT dosimetry.


Asunto(s)
Dosímetros de Radiación , Tomografía Computarizada por Rayos X , Dosis de Radiación , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/instrumentación , Rayos X
15.
Phys Med Biol ; 64(8): 085002, 2019 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-30808009

RESUMEN

A prototype in-body gamma camera system with integrated trans-rectal ultrasound (TRUS) and associated real-time image acquisition and analysis software was developed for intraoperative source tracking in high dose rate (HDR) brachytherapy. The accuracy and temporal resolution of the system was validated experimentally using a deformable tissue-equivalent prostate gel phantom and a full clinical HDR treatment plan. The BrachyView system was able to measure 78% of the 200 source positions with an accuracy of better than 1 mm. A minimum acquisition time of 0.28 s/frame was required to achieve this accuracy, restricting dwell times to a minimum of 0.3 s. Additionally, the performance of the BrachyView-TRUS fusion probe for mapping the spatial location of the tracked source within the prostate volume was evaluated. A global coordinate system was defined by scanning the phantom with the probe in situ using a CT scanner, and was subsequently used for co-registration of the BrachyView and TRUS fields of view (FoVs). TRUS imaging was used to segment the prostate volume and reconstruct it into a three-dimensional (3D) image. Fusion of the estimated source locations with the 3D prostate image was performed using integrated 3D visualisation software. HDR BrachyView is demonstrated to be a valuable tool for intraoperative source tracking in HDR brachytherapy, capable of resolving source dwell locations relative to the prostate anatomy when combined with TRUS.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Programas Informáticos , Ultrasonografía/métodos , Braquiterapia/instrumentación , Cámaras gamma , Humanos , Masculino , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Ultrasonografía/instrumentación
16.
Australas Phys Eng Sci Med ; 42(2): 443-451, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30790139

RESUMEN

A family of prototype 2D monolithic silicon-diode array detectors (MP512, Duo, Octa) has been proposed by the Centre for Medical Radiation Physics, University of Wollongong (Australia) for relative dosimetry in small megavoltage photon beams. These detectors, which differ in the topology of their 512 sensitive volumes, were originally fabricated on bulk p-type substrates. More recently, they have also been fabricated on epitaxial p-type substrates. In the literature, their performance has been individually characterized for quality assurance (QA) applications. The present study directly assessed and compared that of a MP512-bulk and that of a MP512-epitaxial in terms of radiation hardness, long-term stability, response linearity with dose, dose per pulse and angular dependence. Their measurements of output factors, off-axis ratios and percentage depth doses in square radiation fields collimated by the jaws and produced by 6 MV and 10 MV flattened photon beams were then benchmarked against those by commercially available detectors. The present investigation was aimed at establishing, from a medical physicist's perspective, how the bulk and epitaxial fabrication technologies would affect the implementation of the MP512s into a QA protocol. Based on results, the MP512-epitaxial would offer superior radiation hardness, long-term stability and achievable uniformity and reproducibility of the response across the 2D active area.


Asunto(s)
Física Sanitaria/instrumentación , Fotones , Silicio/química , Relación Dosis-Respuesta en la Radiación , Órganos en Riesgo
17.
Phys Med Biol ; 63(23): 235007, 2018 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-30468682

RESUMEN

With more patients receiving external beam radiation therapy with protons, it becomes increasingly important to refine the clinical understanding of the relative biological effectiveness (RBE) for dose delivered during treatment. Treatment planning systems used in clinics typically implement a constant RBE of 1.1 for proton fields irrespective of their highly heterogeneous linear energy transfer (LET). Quality assurance tools that can measure beam characteristics and quantify or be indicative of biological outcomes become necessary in the transition towards more sophisticated RBE weighted treatment planning and for verification of the Monte Carlo and analytical based models they use. In this study the RBE for the CHO-K1 cell line in a passively delivered clinical proton spread out Bragg peak (SOBP) is determined both in vitro and using a silicon-on-insulator (SOI) microdosimetry method paired with the modified microdosimetric kinetic model. The RBE along the central axis of a SOBP with 2 Gy delivered at the middle of the treatment field was found to vary between 1.11-1.98 and the RBE for 10% cell survival between 1.07-1.58 with a 250 kVp x-ray reference radiation and between 1.19-2.34 and 0.95-1.41, respectively, for a Co60 reference. Good agreement was found between RBE values calculated from the SOI-microdosimetry-MKM approach and in vitro. A strong correlation between proton lineal energy and RBE was observed particularly in the distal end and falloff of the SOBP.


Asunto(s)
Terapia de Protones/métodos , Animales , Células CHO , Supervivencia Celular , Cricetinae , Cricetulus , Relación Dosis-Respuesta en la Radiación , Humanos , Transferencia Lineal de Energía , Método de Montecarlo , Terapia de Protones/efectos adversos , Efectividad Biológica Relativa
18.
Phys Med Biol ; 63(21): 215007, 2018 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-30353888

RESUMEN

Silicon-on-insulator (SOI) microdosimeters offer a promising method for routine quality assurance (QA) for hadron therapy due to their ease of operation and high spatial resolution. However, one complication which has been shown previously is that the traditional use of the mean chord length, [Formula: see text], calculated using Cauchy's formula, for SOI devices in clinical carbon ion fields is not appropriate due to the strong directionality of the radiation field. In a previous study, we demonstrated that the mean path length, [Formula: see text], which is the mean path of charged particles in the sensitive volume (SV), is a more appropriate method to obtain microdosimetric quantities and biological relevant values, namely the relative biological effectiveness (RBE) by means of the microdosimetric kinetic model. The previous work, which was limited to mono-energetic [Formula: see text] ion beams typical of heavy ion therapy (HIT), is extended here to investigate the [Formula: see text] in a pristine proton beam as well as for spread out Bragg peaks (SOBP) for both proton and carbon ion clinical beams. In addition, the angular dependence of the SOI device for a number of different SV designs is also investigated to quantify the effects which the alignment has on the [Formula: see text]. It is demonstrated that the [Formula: see text] can be accurately estimated along the depth of a pristine or SOBP using the energy deposition spectra for both proton and [Formula: see text] ion beams. This observation allows a quick and accurate estimation of the [Formula: see text] for experimental use.


Asunto(s)
Radioterapia de Iones Pesados/instrumentación , Radiometría/instrumentación , Silicio , Diseño de Equipo , Humanos , Cinética , Control de Calidad , Efectividad Biológica Relativa
19.
Phys Med ; 45: 117-126, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29472075

RESUMEN

PURPOSE: Flattening filter free (FFF) beams are increasingly being considered for stereotactic radiotherapy (SRT). For the first time, the performance of a monolithic silicon array detector under 6 and 10 MV FFF beams was evaluated. The dosimeter, named "Octa" and designed by the Centre for Medical Radiation Physics (CMRP), was tested also under flattened beams for comparison. METHODS: Output factors (OFs), percentage depth-dose (PDD), dose profiles (DPs) and dose per pulse (DPP) dependence were investigated. Results were benchmarked against commercially available detectors for small field dosimetry. RESULTS: The dosimeter was shown to be a 'correction-free' silicon array detector for OFs and PDD measurements for all the beam qualities investigated. Measured OFs were accurate within 3% and PDD values within 2% compared against the benchmarks. Cross-plane, in-plane and diagonal DPs were measured simultaneously with high spatial resolution (0.3 mm) and real time read-out. A DPP dependence (24% at 0.021 mGy/pulse relative to 0.278 mGy/pulse) was found and could be easily corrected for in the case of machine specific quality assurance applications. CONCLUSIONS: Results were consistent with those for monolithic silicon array detectors designed by the CMRP and previously characterized under flattened beams only, supporting the robustness of this technology for relative dosimetry for a wide range of beam qualities and dose per pulses. In contrast to its predecessors, the design of the Octa offers an exhaustive high-resolution 2D dose map characterization, making it a unique real-time radiation detector for small field dosimetry for field sizes up to 3 cm side.


Asunto(s)
Fotones , Dosímetros de Radiación , Radiometría/instrumentación , Diseño de Equipo , Fotones/uso terapéutico , Radiocirugia , Silicio
20.
Radiat Prot Dosimetry ; 180(1-4): 365-371, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29069515

RESUMEN

Using the CMRP 'bridge' µ+ probe, microdosimetric measurements were undertaken out-of-field using a therapeutic scanning proton pencil beam and in-field using a 12C ion therapy field. These measurements were undertaken at Mayo Clinic, Rochester, USA and at HIMAC, Chiba, Japan, respectively. For a typical proton field used in the treatment of deep-seated tumors, we observed dose-equivalent values ranging from 0.62 to 0.99 mSv/Gy at locations downstream of the distal edge. Lateral measurements at depths close to the entrance and along the SOBP plateau were found to reach maximum values of 3.1 mSv/Gy and 5.3 mSv/Gy at 10 mm from the field edge, respectively, and decreased to ~0.04 mSv/Gy 120 mm from the field edge. The ability to measure the dose-equivalent with high spatial resolution is particularly relevant to healthy tissue dose calculations in hadron therapy treatments. We have also shown qualitatively and quantitively the effects critical organ motion would have in treatment using microdosimetric spectra. Large differences in spectra and RBE10 were observed for treatments where miscalculations of 12C ion range would result in critical structures being irradiated, showing the importance of motion management.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Microtecnología/instrumentación , Fantasmas de Imagen , Terapia de Protones/métodos , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Silicio/química , Simulación por Computador , Humanos , Radiometría/métodos , Dosificación Radioterapéutica